Anti Corrosion and Anti Scaler Chiller TRAC 109

Unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.Usefull for use in high or low temperature closed cooling water syste

Product Enquiry

Request for Quote and Get Heavy Discount on Price

Description

Chiller Treatment CORROSION & SCALE INHIBITOR
Corrosion Inhibitor for Water Systems  having  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate. Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.

The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide.

Application:

Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG – sets, Closed Cooling and chiller System.

FIELDS ::: — Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.

( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems )

Dose:

Refer to technical datasheet.

GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.)

Nitrite (as PPM NO2) 100-200 300-600 700-900 1100-1300   
RXSOL-40-4001-025 / 1000L 8.0  7.3 7-8 5-7   1.5-3.5

NOTE ::: —   If nitrite level becomes 1440-2400 then doses should be ZERO.

The initial dosage for an untreated system is 8 liters of product per 1000 liters of water. Such a dose will bring nitrite levels over 1200 ppm. Maximum nitrite level is considered to be 2400 ppm. Frequent tests should be carried out in order to maintain pH values within the limit (8.3-10.0), while levels of chloride should be maximum 50 ppm.

Note:

Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.

RXSOL-40-4001-025 will react with sludge and in most cases, facilitate sludge gradual removal. On badly fouled systems with oil or scale, a prior degreasing by using DEGREASER HEAVY DUTY or descaling by using DEGREASER HEAVY DUTY, SCALE REMOVER LIQUID or SCALE REMOVER POWDER is highly recommended.

• Excellent corrosion inhibitor for cooling water

• Minimises metal oxide deposits

• Protects ferrous and non-ferrous metals

• Compatible with glycol-based antifreeze

• Reduces cleaning & maintenance costs

• Cost effective, easy to apply and use

Additional information

MSDS

Product Name

:

 RXSOL-40-4001-025

Product Type

:

COOLING WATER TREATMENT (Rocor NB Liquid)

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone

:

+91 22 65113333 / 5555 / 9999 / 27611360

Fax

:

+91 22 2781 1318 :::AOH :0091 9821214367

Email

:

care@rxmarine.com

Chemica Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

 Sodium nitrite

10-30

 7632-00-0

 231-555-9

8, 25, 50

 T, O,N

Sodiumtetraborate 10 aq

1-5

1303-96-4

215-540-4

62,63

Xn 

Benzothiazol-2-thiol

0.1-.02

149-30-4

2299129

34,37

 O

 

Odour

Odourless

Appearance

Pale Yellowis to Clear Liquid, soluble in water

Contact with eyes

May cause pain

Contact with skin

In cases of severe exposure, severe irritation may develop

Inhalation

Vapours or aerosols may cause irritation of eyes, nose and respiratory tract

Ingestion

Toxic if swallowed (R25)

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water
Contaminated clothing should be laundered before reuse
When in doubt or symptoms persist, seek medical attention

Contact with eyes

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes
Irrigate eyes thoroughly whilst lifting eyelids
Obtain immediate medical attention

Ingestion

Never make an unconscious person vomit or drink fluids
Give water or milk to drink
Induce vomiting (only if patient is conscious)
Obtain immediate medical attention

Inhalation

Inhalation is unlikely to occur
Remove patient to fresh air
When in doubt or symptoms persist, seek medical attention

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)

–  Nitrogen oxides may be formed
–  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
–  Substance evolves toxic fumes, wear self-contained breathing apparatus

Personal Precautions

Wear protective clothing as per section 8

Environmental Precautions

Do not allow to enter public sewers and watercourses

Immediate Actions

Use appropriate containment to avoid environmental contamination (S57)

Clean Up Actions

Absorb spillage in inert material and shovel up
Ventilate the area and wash spill site after material pick-up is complete

Special Precautions

Wear protective clothing as per section 8

Handling

Wear protective clothing as per section 8
Avoid contact with skin and eyes (S24/25)
Eyewash bottles should be available

Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49)
Protect from heat
Protect from frost

Exposure controls

No special precautions are required for this product

Occupational exposure controls

Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended)

                                                          

Gloves                          Goggles                        suit                    No_Smoking

Odour

Odourless

Appearance

Pale yellowish to clear  Liquid, soluble in water

pH

8.5 – 9.5 at 100 % concentration

Boiling point

100 °C at 760 mm /Hg

Vapour pressure

not known

Vapour density

not applicable

Freezing point

<0 °C at 760 mm/Hg

Completely soluble in water

Specific gravity (water=1)

1.10 to 1.20

–   This article is considered stable under normal conditions
–   Avoid contact with acid
–   Incompatible with acid, Contact with acids liberates toxic gas (R31)
–    See Section 5

Toxicological information

No experimental data available

Inhalation

Not applicable

Contact with skin

In cases of severe exposure, severe irritation may develop

Contact with eyes

May cause severe irritation
May cause pain

Ingestion

Toxic if swallowed (R25)

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

This product contains components which are classified in the EU as dangerous for the environment.
May cause acute effects in the aquatic environment

Mobility

Completely soluble in water

Persistence and Biodegradability

Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently biodegradable.

Bioaccumulation Potential

Bioaccumulation of the components in this product is insignificant.

Other Adverse Effects

No environmental problems are expected when the product is used / handled correctly. In its intended use, the product will not be released into the environment.

Classification

EU Waste class: 06.03 This material and/or its container must be disposed of as hazardous waste

Disposal considerations

Do not discharge into drains or the environment, dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation

 –  Not classified as hazardous for transport

Classification and labeling

Contains Benzothiazol-2-thiol.  May produce an allergic reaction.
Cooling Water Treatment 15 Regulatory information (….)

Risk Phrases

Toxic if swallowed (R25)

Safety Phrases

Wear suitable protective clothing, eye/face protection and gloves (S36/37/39)
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) This material and its container must be disposed of in a safe way (S35)

Text of R and S phrase codes used  in  this safety data sheet:-  R25: Toxic I f swallowed;  R43: May  cause  sensitisation
by  skin  contact;   R50:  Very  toxic  to  aquatic   organisms;   R50/53:  Very   toxic   to  a  quatic  organisms,  may  cause long-term  adverse  effects  in  the  aquatic   environment;  R62: Possible  risk  of I mpaired fertility; R63: Possible risk of harm  to the unborn child;  R8: Contact  with combustible  material  may cause fire.The  information  provided  about  the product  on  this  Safety  Data  Sheet  has  been  compiled  from knowledge of the individual constituents.The data given here  is  based  on current knowledge and experience. This Safety Data Sheet describes the product.In terms of safetyr equirements   and   does   not   signify  any   warranty   with  regard  to  the  product's  properties  The  data  given  here  only  applies  when  product  used for proper application(s). The product  is  not  sold  as  suitable for  other applications  –   usage   in  such  may  cause  risks  not   mentioned   in   this  sheet.  Do  not  use  for  other application (s) without seeking advice from manufacturer
This Safety Data Sheet is provided in compliance with The  Safety  Data  Sheets  Directive   ( 2001/58EC)
This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directiv (88/379/EEC)
This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive (67/548/EEC)

Reviews

There are no reviews yet.

Be the first to review “Anti Corrosion and Anti Scaler Chiller TRAC 109”

Your email address will not be published. Required fields are marked *

Show Buttons
Hide Buttons